ADSS Fiber Optic Cable 100 SPAN B1.3 PE
Price: Rs 0.00
Fiber Specifications
- Material: Quartz glass (Silicon Dioxide)
- Structure:
- Core: 9 μm (high refractive index)
- Cladding: 125 μm (low refractive index)
- Coating: 245 μm (protective resin)
|
Parameter |
Requirement |
Standard (if applicable) |
|
Core non-circularity |
≤ 6% |
ITU-T G.652 |
|
Cladding diameter |
125.0 ± 0.7 μm |
- |
|
Core/Cladding concentricity |
≤ 0.6 μm |
- |
|
Cladding non-circularity |
≤ 1.0% |
- |
|
Coating diameter |
245 ± 10 μm |
- |
|
Cladding/Coating concentricity |
≤ 12 μm |
- |
|
Attenuation coefficient |
1310 nm: ≤ 0.35 dB/km 1550 nm: ≤ 0.21 dB/km |
- |
|
Zero dispersion slope |
≤ 0.092 ps/(nm²·km) |
- |
|
Zero dispersion wavelength |
1300–1324 nm |
- |
|
Polarization dispersion |
≤ 0.20 ps/√km |
- |
|
Mode field diameter (1310 nm) |
9.0 ± 0.4 μm |
- |
|
Cut-off wavelength |
1170–1330 nm |
- |
|
Chromatic dispersion |
1288–1339 nm: ≤ 3.4 ps/(nm·km) 1550 nm: ≤ 18 ps/(nm·km) 1625 nm: ≤ 22 ps/(nm·km) |
|
Cable Parameters
|
Parameter |
Value |
|
Fibers per loose tube |
6 |
|
Number of tubes |
2 (total 12 fibers) |
|
Inner sheath thickness |
1.0 mm |
|
Outer sheath thickness |
1.7 mm |
|
Aramid area |
2.8 mm² |
|
Cable diameter |
11.6 mm (±5%) |
|
Cable cross-section |
106 mm² |
|
Cable weight |
105 kg/km (±10%) |
4. Mechanical & Environmental Performance
- Key Parameters:
- RTS (Rated Tensile Strength): 4800 N
- MAT (Maximum Allowable Tension): 1900 N
- Static bending radius: ≥ 174 mm
- Dynamic bending radius: ≥ 290 mm
- Operating temperature: -40°C to +70°C
- Installation temperature: -10°C to +40°C
5. Test Requirements
|
Test Type |
Standard |
Key Criteria |
|
Tensile Test |
IEC 60794-1-21-E1 |
- RTS: No break at 100% RTS. - UOS (60% RTS): Fiber strain < 0.35%, no added attenuation. - MAT (40% RTS): Strain < 0.05%. |
|
Crush Test |
IEC 60794-1-21-E3 |
≤ 0.1 dB attenuation @1550 nm under 2200 N; no residual attenuation. |
|
Impact Test |
IEC 60794-1-21-E4 |
450g weight, 1m height, 5 impacts. No sheath cracks or residual attenuation. |
|
Repeated Bending |
IEC 60794-1-21-E6 |
30 bends under 150 N load. No cracks/residual attenuation. |
|
Torsion Test |
IEC 60794-1-21-E7 |
±180° twist, 10 cycles. No added attenuation or sheath damage. |
|
Temperature Cycling |
IEC 60794-1-22-F1 |
-40°C to +65°C, 2 cycles. Attenuation < 0.05 dB/km @1550 nm. |
|
Water Penetration |
IEC 60794-1-22-F7 |
1m head for 1 hour. No leakage. |