Fiber Specifications
Parameter |
Requirement |
Standard (if applicable) |
Core non-circularity |
≤ 6% |
ITU-T G.652 |
Cladding diameter |
125.0 ± 0.7 μm |
- |
Core/Cladding concentricity |
≤ 0.6 μm |
- |
Cladding non-circularity |
≤ 1.0% |
- |
Coating diameter |
245 ± 10 μm |
- |
Cladding/Coating concentricity |
≤ 12 μm |
- |
Attenuation coefficient |
1310 nm: ≤ 0.35 dB/km 1550 nm: ≤ 0.21 dB/km |
- |
Zero dispersion slope |
≤ 0.092 ps/(nm²·km) |
- |
Zero dispersion wavelength |
1300–1324 nm |
- |
Polarization dispersion |
≤ 0.20 ps/√km |
- |
Mode field diameter (1310 nm) |
9.0 ± 0.4 μm |
- |
Cut-off wavelength |
1170–1330 nm |
- |
Chromatic dispersion |
1288–1339 nm: ≤ 3.4 ps/(nm·km) 1550 nm: ≤ 18 ps/(nm·km) 1625 nm: ≤ 22 ps/(nm·km) |
|
Cable Parameters
Parameter |
Value |
Fibers per loose tube |
6 |
Number of tubes |
2 (total 12 fibers) |
Inner sheath thickness |
1.0 mm |
Outer sheath thickness |
1.7 mm |
Aramid area |
2.8 mm² |
Cable diameter |
11.6 mm (±5%) |
Cable cross-section |
106 mm² |
Cable weight |
105 kg/km (±10%) |
4. Mechanical & Environmental Performance
5. Test Requirements
Test Type |
Standard |
Key Criteria |
Tensile Test |
IEC 60794-1-21-E1 |
- RTS: No break at 100% RTS. - UOS (60% RTS): Fiber strain < 0.35%, no added attenuation. - MAT (40% RTS): Strain < 0.05%. |
Crush Test |
IEC 60794-1-21-E3 |
≤ 0.1 dB attenuation @1550 nm under 2200 N; no residual attenuation. |
Impact Test |
IEC 60794-1-21-E4 |
450g weight, 1m height, 5 impacts. No sheath cracks or residual attenuation. |
Repeated Bending |
IEC 60794-1-21-E6 |
30 bends under 150 N load. No cracks/residual attenuation. |
Torsion Test |
IEC 60794-1-21-E7 |
±180° twist, 10 cycles. No added attenuation or sheath damage. |
Temperature Cycling |
IEC 60794-1-22-F1 |
-40°C to +65°C, 2 cycles. Attenuation < 0.05 dB/km @1550 nm. |
Water Penetration |
IEC 60794-1-22-F7 |
1m head for 1 hour. No leakage. |
Fiber Specifications
Parameter |
Requirement |
Standard (if applicable) |
Core non-circularity |
≤ 6% |
ITU-T G.652 |
Cladding diameter |
125.0 ± 0.7 μm |
- |
Core/Cladding concentricity |
≤ 0.6 μm |
- |
Cladding non-circularity |
≤ 1.0% |
- |
Coating diameter |
245 ± 10 μm |
- |
Cladding/Coating concentricity |
≤ 12 μm |
- |
Attenuation coefficient |
1310 nm: ≤ 0.35 dB/km 1550 nm: ≤ 0.21 dB/km |
- |
Zero dispersion slope |
≤ 0.092 ps/(nm²·km) |
- |
Zero dispersion wavelength |
1300–1324 nm |
- |
Polarization dispersion |
≤ 0.20 ps/√km |
- |
Mode field diameter (1310 nm) |
9.0 ± 0.4 μm |
- |
Cut-off wavelength |
1170–1330 nm |
- |
Chromatic dispersion |
1288–1339 nm: ≤ 3.4 ps/(nm·km) 1550 nm: ≤ 18 ps/(nm·km) 1625 nm: ≤ 22 ps/(nm·km) |
|
Cable Parameters
Parameter |
Value |
Fibers per loose tube |
6 |
Number of tubes |
2 (total 12 fibers) |
Inner sheath thickness |
1.0 mm |
Outer sheath thickness |
1.7 mm |
Aramid area |
2.8 mm² |
Cable diameter |
11.6 mm (±5%) |
Cable cross-section |
106 mm² |
Cable weight |
105 kg/km (±10%) |
4. Mechanical & Environmental Performance
5. Test Requirements
Test Type |
Standard |
Key Criteria |
Tensile Test |
IEC 60794-1-21-E1 |
- RTS: No break at 100% RTS. - UOS (60% RTS): Fiber strain < 0.35%, no added attenuation. - MAT (40% RTS): Strain < 0.05%. |
Crush Test |
IEC 60794-1-21-E3 |
≤ 0.1 dB attenuation @1550 nm under 2200 N; no residual attenuation. |
Impact Test |
IEC 60794-1-21-E4 |
450g weight, 1m height, 5 impacts. No sheath cracks or residual attenuation. |
Repeated Bending |
IEC 60794-1-21-E6 |
30 bends under 150 N load. No cracks/residual attenuation. |
Torsion Test |
IEC 60794-1-21-E7 |
±180° twist, 10 cycles. No added attenuation or sheath damage. |
Temperature Cycling |
IEC 60794-1-22-F1 |
-40°C to +65°C, 2 cycles. Attenuation < 0.05 dB/km @1550 nm. |
Water Penetration |
IEC 60794-1-22-F7 |
1m head for 1 hour. No leakage. |
Base Unit | km |
---|---|
Category | Optical Fiber Cable and Accessories |
SKU | |
Product Code | 207 |
Trackable | Yes |
Taxable | Yes |
Fusce dapibus, tellus ac cursus commodo, tortor mauris condimentum nibh, ut fermentum massa justo sit amet risus. Integer posuere erat a ante venenatis dapibus posuere velit aliquet. Cras mattis consectetur purus sit amet fermentum. Maecenas sed diam eget risus varius blandit sit amet non magna. Sed posuere consectetur est at lobortis. Curabitur blandit tempus porttitor. Aenean lacinia bibendum nulla sed consectetur. Nulla vitae elit libero, a pharetra augue. Morbi leo risus, porta ac consectetur ac, vestibulum at eros. Praesent commodo cursus magna, vel scelerisque nisl consectetur et.
No videos available for this product.
Duis mollis gravida commodo id luctus erat porttitor ligula, eget lacinia odio sem.
Duis mollis gravida commodo id luctus erat porttitor ligula, eget lacinia odio sem.
Duis mollis gravida commodo id luctus erat porttitor ligula, eget lacinia odio sem.
No reviews yet. Be the first to review this product!
Login to leave a review.