Discover our latest products and services
Contact us for pricing details.
Technical Specification for GYTC8A B1.3 Fiber Optic Cable
1. Fiber Specifications
Description:
Technical Requirements:
No |
Item |
Test Requirement |
Test Standard |
1 |
Core non-circularity |
≤ 6% |
ITU-T G.652 |
2 |
Cladding diameter |
125.0 ± 0.7 μm |
- |
3 |
Core/Cladding concentricity error |
≤ 0.6 μm |
- |
4 |
Cladding non-circularity |
≤ 1.0% |
- |
5 |
Coating diameter |
245 ± 10 μm |
- |
6 |
Cladding/Coating concentricity |
≤ 12 μm |
- |
7 |
Attenuation coefficient |
1310 nm: ≤ 0.35 dB/km 1550 nm: ≤ 0.21 dB/km |
- |
8 |
Zero dispersion slope |
≤ 0.092 ps/(nm²·km) |
- |
9 |
Zero dispersion wavelength |
1300–1324 nm |
- |
10 |
Polarization dispersion |
≤ 0.20 ps/√km |
- |
11 |
Mode field diameter |
1310 nm: 9.0 ± 0.4 μm |
- |
12 |
Cut-off wavelength |
1170–1330 nm |
- |
13 |
Chromatic dispersion coefficient |
1288–1339 nm: ≤ 3.4 ps/(nm·km) 1550 nm: ≤ 18 ps/(nm·km) 1625 nm: ≤ 22 ps/(nm·km) |
- |
2. Cable Structure
Components:
Structure Parameters:
No |
Item |
Parameters |
1 |
Tube/Fiber Color |
1: Blue (Tube) / Blue (Fiber) 2: White / White 3: Yellow / Yellow 4: Green / (Missing Fiber Color) |
2 |
Fiber core |
12 fibers |
3 |
Fibers per tube |
6/12/24 fibers |
4 |
Number of tubes |
1/2/3 tubes |
5 |
Loose tube outer diameter |
1.7 mm |
6 |
Central strength member |
1.2 mm steel wire |
7 |
Armoring material |
Corrugated aluminium tape |
8 |
Armoring thickness |
0.15 mm aluminium + 0.05 mm coating (each side) |
9 |
Galvanized steel strand wire |
7 × 0.9 mm |
10 |
Strand wire sheath thickness |
1.5 mm |
11 |
Neck dimensions (W×H) |
1.6 × 2.2 mm |
12 |
Outer sheath material |
MDPE |
13 |
Outer sheath thickness |
2.0 mm |
14 |
Cable dimensions |
9.7 × 17.4 mm (±0.3 mm) |
15 |
Cable weight |
137 kg/km (-5% tolerance) |
3. Performance Tests
3.1 Tensile Test
Parameter |
Requirement |
Test Standard |
IEC 60794-1-21-E1 |
Long-term load |
5000 N |
Short-term load |
10000 N |
Test length |
≥ 100 m |
Duration |
10 minutes |
Attenuation limit |
≤ 0.1 dB increase |
3.2 Crush Test
Parameter |
Requirement |
Test Standard |
IEC 60794-1-21-E3 |
Pressure load |
1000 N/100 mm |
Test length |
100 mm |
Duration |
10 minutes |
Attenuation limit |
≤ 0.1 dB increase |
3.3 Repeated Bending Test
Parameter |
Requirement |
Test Standard |
IEC 60794-1-21-E6 |
Bending radius |
≤ 22× cable diameter |
Tensile load |
55 N |
Bending cycles |
30 times |
Attenuation limit |
≤ 0.05 dB increase |
3.4 Bending Test
Parameter |
Requirement |
Test Standard |
IEC 60794-1-21-E11 |
Mandrel diameter |
22× cable diameter |
Duration |
5 minutes |
Attenuation limit |
≤ 0.05 dB increase |
3.5 Temperature Cycling Test
Parameter |
Requirement |
Test Standard |
IEC 60794-1-22-F1 |
Temperature range |
-20°C to +70°C |
Sample length |
≥ 2 km |
Duration |
24 hours |
Attenuation limit |
≤ 0.05 dB increase |
3.6 Water Penetration Test
Parameter |
Requirement |
Test Standard |
IEC 60794-1-22-F7 |
Head height |
1 m |
Sample length |
1 m |
Duration |
24 hours |
Decision criteria |
No water leakage |
Base Unit | km |
---|---|
Category | Optical Fiber Cable and Accessories |
SKU | |
Product Code | 216 |
Trackable | Yes |
Taxable | Yes |
No videos available for this product.
Enjoy fast and free delivery across Nepal on all orders above Rs. 5,000. No hidden charges.
Shop with confidence. Return or exchange your product within 30 days if you're not fully satisfied.
All our products come with a standard warranty of up to 2 years, covering manufacturing defects.
No reviews yet. Be the first to review this product!
Login to leave a review.