Product Description of SFP 155M BIDI 20KM 1310TX/1550RX SC:
The SFP transceivers are high performance, cost effective modules supporting data-rate of 155Mbps Mbps and a 20 km transmission distance with SMF. The transceivers are compatible with SFP Multi-Source Agreement (MSA) and SFF-8472. For further information,please refer to SFP MSA and SFF-8472.
Features of SFP 155M BIDI 20KM 1310TX/1550RX SC:
- Up to 155Mbps data links
- 1310nm FP Laser and PIN photo-detector for YSP01-B3520
- 1550nm FP Laser and PIN photo-detector for YSP01-B5320
- Up to 20km on 9/125µm SMF
- Simplex SC receptacle optical interface compliant
- Hot-pluggable
- All-metal housing for superior EMI performance
- RoHS6 compliant (lead-free)
- Operating case temperature:
- Commercial: -5°C to +70°C
- Extended: -20°C to +80°C
- Industrial: -40°C to +85°C
Applications of SFP 155M BIDI 20KM 1310TX/1550RX SC:
- SONET OC-12/ SDH STM-4
- Fast Ethernet
- Switch to Switch interface
- Switched backplane applications
- Router/Server interface
- Other optical transmission systems
Standards of SFP 155M BIDI 20KM 1310TX/1550RX SC:
- Compliant with SFP MSA
- Compliant with SFF-8472
- Compatible with G.957
Absolute Maximum Ratings of SFP 155M BIDI 20KM 1310TX/1550RX SC:
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
Power Supply Voltage |
VCC |
0 |
|
3.6 |
V |
Storage Temperature |
Ts |
-40 |
|
+85 |
°C |
Operating Case Temperature |
Tc |
-40 |
|
+85 |
°C |
Relative Humidity |
RH |
0 |
|
85 |
% |
RX Input Average Power |
Pmax |
- |
0 |
dBm |
|
Recommended Operating Environment of SFP 155M BIDI 20KM 1310TX/1550RX SC:
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
Power Supply Voltage |
VCC |
3.13 |
3.3 |
3.46 |
V |
Power Supply Current |
Icc |
|
300 |
|
mA |
Operating Case Temperature |
|
|
|
|
|
Commercial |
TC |
-5 |
+70 |
|
°C |
Extended |
|
-20 |
+80 |
|
°C |
Industrial |
|
-40 |
+85 |
|
°C |
Data Rate |
|
125/155 |
|
|
Electrical Characteristics of SFP 155M BIDI 20KM 1310TX/1550RX SC:
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
Note |
Transmitter Section |
|
|
|
|
|
|
Input Differential Impedance |
Rin |
90 |
100 |
110 |
Ω |
|
Single Ended Data Input Swing |
Vin_PP |
250 |
1000 |
mV |
1 |
|
Transmit Disable Voltage |
VD |
Vcc – 1.3 |
|
Vcc |
V |
|
Transmit Enable Voltage |
VEN |
Vee |
Vee+0.8 |
V |
2 |
|
Receiver Section |
|
|
|
|
|
|
Single Ended Data Output Swing |
Vout_PP |
300 |
600 |
mV |
|
|
LOS Fault |
Vlos_fault |
Vcc – 0.5 |
|
Vcc_host |
V |
2 |
LOS Normal |
Vlos_norm |
Vee |
Vee+0.5 |
V |
2 |
Optical Parameters of SFP 155M BIDI 20KM 1310TX/1550RX SC:
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
Note |
Transmitter Section |
|
|
|
|
|
|
Centre Wavelength |
λc |
1260 |
1310 |
1360 |
nm |
YSP01-B3520 |
|
|
1480 |
1550 |
1580 |
nm |
YSP01-B5320S |
Spectral Width (RMS) |
σ |
|
|
3 |
nm |
|
Average Optical Power (avg.) |
Pout |
-9 |
-3 |
dBm |
1 |
|
Laser Off Power |
Poff |
- |
- |
-45 |
dBm |
|
Extinction Ratio |
ER |
10 |
- |
- |
dB |
2 |
Relative Intensity Noise |
RIN |
- |
- |
-120 |
dB/Hz |
|
Optical Rise/Fall Time |
tr / tf |
- |
1300 |
ps |
3 |
|
Optical Return Loss Tolerance |
|
- |
- |
12 |
dB |
|
Output Optical Eye |
|
|
|
|
|
Compliant with G.957 eye masks when filtered |
Receiver Section |
|
|
|
|
|
|
Receiver Center Wavelength |
λc |
1480 |
1550 |
1580 |
nm |
YSP01-B3520S |
|
|
1260 |
1310 |
1360 |
nm |
YSP01-B5320S |
Receiver Sensitivity in Average Power |
Sen |
-32 |
-3 |
dBm |
4 |
|
Los Assert |
LOSA |
-40 |
- |
- |
dBm |
|
Los Dessert |
LOSD |
- |
- |
-34 |
dBm |
|
Los Hysteresis |
LOSH |
0.5 |
- |
5 |
dB |
|
Overload |
Pin-max |
- |
- |
-3 |
dBm |
4 |
Receiver Reflectance |
|
- |
- |
-12 |
dB |
|
Receiver Power (damage) |
|
- |
- |
0 |
dBm |
Timing Characteristics of SFP 155M BIDI 20KM 1310TX/1550RX SC:
Timing Characteristics |
Parameter |
Symbol |
Min. |
Typical |
Max. |
Unit |
TX_Disable Assert Time |
t_off |
|
10 |
- |
- |
us |
TX_Disable Negate Time |
t_on |
|
- |
1 |
ms |
|
Time to Initialize Include Reset of TX_FAULT |
t_init |
|
300 |
- |
- |
ms |
TX_FAULT from Fault to Assertion |
t_fault |
|
- |
100 |
us |
|
TX_Disable Time to Start Reset |
t_reset |
|
- |
10 |
us |
|
Receiver Loss of Signal Assert Time |
TA, RX_LOS |
|
- |
100 |
us |
|
Receiver Loss of Signal Deassert Time |
Td, RX_LOS |
|
- |
100 |
us |
|
Rate-Select Change Time |
t_ratesel |
|
- |
10 |
us |
|
Serial ID Clock Time |
f_serial-clock |
|
- |
100 |
kHz |
|
Digital Diagnostic Monitor Characteristics of SFP 155M BIDI 20KM 1310TX/1550RX SC:
Digital Diagnostic Monitor Characteristics (DDM) |
Parameter |
Symbol |
Min. |
Max. |
Unit |
Temperature Monitor Absolute Error |
DMI_Temp |
|
-3 |
3 |
°C |
Laser Power Monitor Absolute Error |
DMI_TX |
|
-3 |
3 |
dB |
RX Power Monitor Absolute Error |
DMI_RX |
|
-3 |
3 |
dB |
Supply Voltage Monitor Absolute Error |
DMI_VCC |
|
-3% |
3% |
V |
Bias Current Monitor Absolute Error |
DMI_Ibias |
|
-10% |
10% |
mA |
Additional Specifications
Base Unit |
pc(1) |
Category |
OFC Passive Devices |
SKU |
|
Product Code |
124 |
Trackable |
Yes |
Taxable |
Yes |
Fusce dapibus, tellus ac cursus commodo, tortor mauris condimentum nibh, ut fermentum massa justo sit amet risus. Integer posuere erat a ante venenatis dapibus posuere velit aliquet. Cras mattis consectetur purus sit amet fermentum. Maecenas sed diam eget risus varius blandit sit amet non magna. Sed posuere consectetur est at lobortis. Curabitur blandit tempus porttitor. Aenean lacinia bibendum nulla sed consectetur. Nulla vitae elit libero, a pharetra augue. Morbi leo risus, porta ac consectetur ac, vestibulum at eros. Praesent commodo cursus magna, vel scelerisque nisl consectetur et.
No videos available for this product.
No reviews yet. Be the first to review this product!
Login to leave a review.